CJQYT - STAINBLASTER B, 16640

  • MSDS: CJQYT
  • Manufacturer: ECOLAB INC
  • Product Name: STAINBLASTER B, 16640
  • National Stock Number: 7930-00N092082
Product Identification

Product ID:STAINBLASTER B, 16640
MSDS Date:01/02/1997
FSC:7930
NIIN:00N092082
Status Code:A
MSDS Number: CJQYT

Responsible Party
ECOLAB INC
ECOLAB CENTER
ST PAUL, MN 55102
US

Emergency Phone: 800-328-0026

Info Phone: 800-352-5326

Cage: 85884

Contractor
ECOLAB PROFESSIONAL PRODUCTS DIVISION OF ECOLAB INC.
ST PAUL, MN 55102 US

Telephone: 800-352-5326

Cage: 85884

Ingredients

SODIUM HYPOCHLORITE

CAS: 7681-52-9

RTECS: NH3486300

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


NON-HAZARDOUS INGREDIENTS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF OVEREXP TO CONCENTRATE:
SKIN AND EYES: CAUSES CHEMICAL BURNS. EYE CONTACT MAY CAUSE
BLINDNESS. IF SWALLOWED: HARMFUL. CAUSES CHEMICAL BURNS OF MOUTH,
THROAT AND STOMACH. IF INHALED: VAPORS OR MIST CAUSE IRRITATION,
INCLUDING A BURNING TASTE, SNEEZING, COUGHING AND DIFFICULTY
BREATHING. PEOPLE WITH ASTHMA OR OTHER LUNG PROBLEMS MAY BE MORE
AFFECTED.
Effects of Overexposure:SEE HEALTH HAZARDS.

First Aid

First Aid:EYES: FLUSH AT ONCE W/COOL RUNNING WATER. REMOVE CONT LENSES.
CONTINUE FLUSHING FOR AT LST 15 MINS, HOLDING EYELIDS APART SO AS
TO RINSE ENTIRE EYE. CALL PHYS IMMED. SKIN: IMMEDIATELY FLUSH
W/PLENTY O F COOL RUNNING WATER FOR AT LST 15 MINS WHILE REMOVING
CONTAMINATED CLOTHING & SHOES; DISCARD OR WASH WELL BEFORE REUSE.
IF SWALLOWED: RINSE MOUTH AT ONCE, THEN DRINK 1-2 LG GLASSES OF
WATER. DO NOT I NDUCE VOMIT. NEVER GIVE ANYTHING BY MOUTH TO UNCON
PERSON. IF INHALED: IMMEDIATELY MOVE TO FRESH AIR. IMMED CALL MED
EMER NUMBER, 1-800-328-0026, A POIS CTL CTR/PHYSICIAN.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:PRODUCT DOES NOT SUPPORT COMBUSTION.

Accidental Release

Spill Release Procedures:USE PROPER PROTECTIVE EQUIPMENT. CLEANUP: DIKE
OR DAM LARGE SPILLS. PUMP TO CONTAINERS OR SOAK UP ON INERT
ABSORBENT. FLUSH RESIDUE TO SANITARY SEWER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:AVOID BREATHING MISTS OR VAPORS OF THIS PRODUCT.
NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Protective Gloves:INDUSTRIAL RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES AND FULL LENGTH
FACESHIELD .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
OTHER PROTECTION NECESSARY TO AVOID SKIN CONTACT.
Supplemental Safety and Health
SOL IN H*2O: MIXES WITH WATER IN ALL PROPORTIONS.

Chemical Properties

Boiling Pt:>100.C, 212.F
Spec Gravity:1.00-1.10
pH:10.5-11.5(100%)
Solubility in Water:SUPDAT
Appearance and Odor:CLEAR LIGHT YELLOW LIQUID WITH CHLORINE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
DO NOT MIX WITH ACIDS OR AMMONIA - WILL CAUSE HAZARDOUS VAPORS.
Stability Condition to Avoid:MIX ONLY WITH WATER. DO NOT MIX WITH ACIDS
OR AMMONIA - WILL CAUSE HAZARDOUS VAPORS.
Hazardous Decomposition Products:HIGH TEMPERATURES MAY GENERATE
HAZARDOUS DECOMPOSITION PRODUCTS INCLUDING CHLORINE GAS.

Disposal

Waste Disposal Methods:UNUSED PRODUCT IS RCRA CORROSIVE (D002).
DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS .

Regulatory

SARA Title III Information:NO SARA 313 TOXIC CHEMICALS PRESENT IN
PRODUCT.
Federal Regulatory Information:THIS PRODUCT CONTAINS NO OTHER
COMPONENTS CONSIDERED HAZARDOUS ACCORDING TO THE CRITERIA OF 29 CFR
1910.1200.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.